10 KiB
Tutorial on Camera-IMU and Motion Capture Calibration with Realsense T265
In this tutorial we explain how to perform photometric and geometric calibration of the multi-camera setup and then calibrate the transformations between cameras, IMU and the motion capture marker setup. To make sure the calibration is successful we recommend to rigidly attach markers to the camera as shown on the figure above.
Dataset
We provide a set of example datasets for the calibration. Even if you plan to record your own datasets (covered in the next section), we recommend to download and try the provided examples:
mkdir ~/t265_calib_data
cd ~/t265_calib_data
wget http://vision.in.tum.de/tumvi/t265/response_calib.zip
wget http://vision.in.tum.de/tumvi/t265/cam_calib.zip
wget http://vision.in.tum.de/tumvi/t265/imu_calib.zip
wget http://vision.in.tum.de/tumvi/t265/sequence0.zip
unzip response_calib
unzip cam_calib
unzip imu_calib
unzip sequence0
Recording Own Dataset
You can record your own sequences using the basalt_rs_t265_record
executable:
basalt_rs_t265_record --dataset-path ~/t265_calib_data/ --manual-exposure
--dataset-path
specifies the location where the recorded dataset will be stored. In this case it will be stored in~/t265_calib_data/<current_timestamp>/
.--manual-exposure
disables the autoexposure. In this tutorial the autoexposure is disabled for all calibration sequences, but for the VIO sequence (sequence0) we enable it.
The GUI elements have the following meaning:
webp_quality
compression quality. The highest value (101) means lossless compression. For photometric calibration it is important not to have any compression artifacts, so we record these calibration sequences with lossless compression.skip_frames
reduces the framerate of the recorded dataset by skipping frames.exposure
controls the exposure time of the cameras.record
starts/stops the recoding of the dataset. If you run the system on the slow PC pay attention to the number of messages in the queue. If it goes beyond the limit the recorder will start dropping frames.export_calibration
exports factory calibration in the basalt format.
After recoding the dataset it is a good practice to verify the quality of the dataset. You can do this by running:
basalt_verify_dataset.py -d ~/t265_calib_data/<dataset_path>/
It will report the actual frequencies of the recorded sensor messages and warn you if any files with image data are missing.
Every sequence required for the calibration should have certain properties to enable successful calibration. Pay attention to the Important for recording the dataset subsections and inspect the provided examples before recoding your own sequences.
Response calibration
In this project we assume a camera has a linear response function (intensity of the pixel is linearly proportional to the amount of light captured by the pixel). In this section we will verify this for the Realsense T265 cameras. We will need to record a static scene with different exposure times.
Important for recording the dataset:
- Keep the camera static and make sure that nothing in the scene moves during the recording.
- Move
webp_quality
slider to the highest value to enable lossless compression. - Optionally set the
skip_frames
slider to 3-5 to speed up the dataset recoding. - Start recoding and slowly move the exposure slider up and down. Stop recoding.
- Rename the dataset to
response_calib
.
Run the response function calibration:
basalt_response_calib.py -d ~/t265_calib_data/response_calib
You should see the response function and the irradiance image similar to the one shown below. For the details of the algorithm see Section 2.3.1 of [arXiv:1607.02555]. The results suggest that the response function used in the camera is linear.
Multi-Camera Geometric and Vignette Calibration
For the camera calibration we need to record a dataset with a static aprilgrid pattern.
Important for recording the dataset:
- Move
webp_quality
slider to the highest value to enable lossless compression (important for vignette calibration). - Set the
skip_frames
slider to 5 to speed up the dataset recoding. - Move the camera slowly to reduce the motion blur.
- Cover the entire field of view of the camera with the calibration pattern. Try to observe the pattern from different angles.
- Make sure you do not cast shadows at the pattern (important for vignette calibration).
- Rename the dataset to
cam_calib
Run the calibration executable:
basalt_calibrate --dataset-path ~/t265_calib_data/cam_calib --dataset-type euroc --result-path ~/t265_calib_results/ --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --cam-types kb4 kb4
To perform the calibration follow these steps:
load_dataset
load the dataset.detect_corners
detect corners. If the corners were detected before the cached detections will be loaded at the previous step so there is no need to re-run the detection.init_cam_intr
initialize camera intrinsics.init_cam_poses
initialize camera poses using the current intrinsics estimate.init_cam_extr
initialize transformations between multiple cameras.init_opt
initialize optimization.opt_until_converge
optimize until convergence.opt_cam_poses
some initial poses computed from the initialized intrinsics can be far from optimum and not converge to the right minimum. To improve the final result we can re-initialize poses with optimized intrinsics.init_opt
initialize optimization with new initial poses.opt_until_converge
optimize until convergence.compute_vign
after optimizing geometric models compute the vignetting of the cameras.save_calib
save calibration file to the~/t265_calib_results/calibration.json
.
IMU and Motion Capture Calibration
After calibrating cameras we can proceed to geometric and time calibration of the cameras, IMU and motion capture system. Setting up the motion capture system is specific for your setup.
For the motion capture recording we use ros_vrpn_client with basalt_capture_mocap.py. We record the data to the mocap0
folder and then move it to the mav0
directory of the camera dataset. This script is provided as an example. Motion capture setup is different in every particular case.
Important for recording the dataset:
- Set the
skip_frames
slider to 1 to use the full framerate. - Reduce the exposure time to reduce the motion blur.
- Move the setup such that all axes of accelerometer and gyro are excited. This means moving with acceleration along X, Y and Z axes and rotating around those axes.
- Do not forget to simultaneously record motion capture data.
- Rename the dataset to
imu_calib
.
Run the calibration executable:
basalt_calibrate_imu --dataset-path ~/t265_calib_data/imu_calib --dataset-type euroc --result-path ~/t265_calib_results/ --aprilgrid /usr/etc/basalt/aprilgrid_6x6.json --accel-noise-std 0.00818 --gyro-noise-std 0.00226 --accel-bias-std 0.01 --gyro-bias-std 0.0007
To perform the calibration follow these steps:
load_dataset
load the dataset.detect_corners
detect corners. If the corners were detected before the cached detections will be loaded at the previous step so there is no need to re-run the detection.init_cam_poses
initialize camera poses.init_cam_imu
initialize the transformation between cameras and the IMU.init_opt
initialize optimization.opt_until_converge
optimize until convergence.- Enable
opt_cam_time_offset
andopt_imu_scale
to optimize the time offset between cameras and the IMU and the IMU scale. opt_until_converge
optimize until convergence.init_mocap
initialize transformation between the motion capture marker frame and the IMU and the transformation between the aprilgrid pattern and the motion capture system origin.- Enable
opt_mocap
. opt_until_converge
optimize until convergence.save_calib
save calibration file to the~/t265_calib_results/calibration.json
.save_mocap_calib
save motion capture system calibration file to the~/t265_calib_results/mocap_calibration.json
.
Generating Time-Aligned Ground Truth
Since motion capture system and the PC where the dataset was recorded might not have the same clock we need to perform the time synchronization. Additionally we need to transform the coordinate frame of the GT data to the IMU frame (originally it is in the coordinate frame attached to the markers).
The raw motion capture data is stored in the mav/mocap0/
folder. We can find the time offset by minimizing the error between gyro measurements and rotational velocities computed from the motion capture data. If you press the save_aligned_dataset
button the resulting trajectory (time aligned and transformed to the IMU frame) will be written to mav/gt/data.csv
and automatically loaded when available.
basalt_time_alignment --dataset-path ~/t265_calib_data/sequence0 --dataset-type euroc --calibration ~/t265_calib_results/calibration.json --mocap-calibration ~/t265_calib_results/mocap_calibration.json
You should be able to see that, despite some noise, rotational velocity computed from the motion capture data aligns well with gyro measurements.
You can also switch to the error function plot and see that there is a clear minimum corresponding to the computed time offset.
Note: If you want to run the time alignment again you should delete the ~/t265_calib_data/sequence0/mav/gt
folder first.
Running Visual-Inertial Odometry
Now we can run the visual-inertial odometry on the recorded dataset:
basalt_vio --dataset-path ~/t265_calib_data/sequence0 --cam-calib ~/t265_calib_results/calibration.json --dataset-type euroc --config-path /usr/etc/basalt/euroc_config.json --show-gui 1
After the system processes the whole sequence you can use align_se3
button to align trajectory to the ground-truth data and compute RMS ATE.
Running Visual-Inertial Odometry Live
It is also possible to run the odometry live with the camera. If no calibration files are provided the factory calibration will be used.
basalt_rs_t265_vio --cam-calib ~/t265_calib_results/calibration.json --config-path /usr/etc/basalt/euroc_config.json